The aerosol containment box or intubation box is medical tool invented to help protect healthcare workers from airborne aerosols while performing procedures such as intubation that are close to the mouth of the patient. The current design of the aerosol containment box is used heavily during the COVID-19 pandemic due to the virus being present in airborne aerosol particles from a patient’s breath. However, the current design has been reported to be flawed in its design aspects. Adding ergonomic considerations into the design is expected to provide improved mobility and better usage of medical instruments. The research conducted analyzed how effective the current design in containing the spread of aerosols from the patient. To execute the research, the current design is modelled in a 3D render using SOLIDWORKS 2020 using dimensions to scale. The 3D model is imported into ANSYS 18.2 to conduct an airflow analysis when a patient cough or breathes to analyses the spread of the aerosols from the patient. The patient coughing was simulated using a nozzle with the boundary space of the model based on the size of the intubation box. The key outcome of the project that the present design is not verry effective in containing aerosol spread as there is still airflow of the particles leaving the intubation box into the environment. The improved design of the intubation box prevents flow of the aerosols into the environment by using suction and seals to close of outlets. The data gained from the study of the aerosol spread proves that there is a higher pressure concentration of the aerosols particles on the walls of the outlets in the existing design in the market as compared to the improved design suggested. This data can help better justify the dimensions and criteria needed to further enhance the current design of the aerosol containment box.

Fecha

2021

Identificador

10.1051/matecconf/202133503005

Fuente

Epidemiology and Health

Editor

Korean Society of Epidemiology

Cobertura

Engineering (General). Civil engineering (General)

Archivos

https://socictopen.socict.org/files/to_import/pdfs/9258e0a54c1a0906377ea598663adb5d.pdf

Colección

Citación

Sathian Harishan, Eh Noum Se Yong, “Reinventing Aerosol Containment Unit for Use in Medical Operating Theatre,” SOCICT Open, consulta 30 de septiembre de 2025, https://socictopen.socict.org/items/show/10516.

Formatos de Salida

Position: 4284 (22 views)