Performance Evaluation of Serial SARS-CoV-2 Rapid Antigen Testing During a Nursing Home Outbreak.

Título

Performance Evaluation of Serial SARS-CoV-2 Rapid Antigen Testing During a Nursing Home Outbreak.

Autor

Susannah L McKay, Farrell A Tobolowsky, Erin D Moritz, Kelly M Hatfield, Amelia Bhatnagar, Stephen P LaVoie, David A Jackson, K Danielle Lecy, Jonathan Bryant-Genevier, Davina Campbell, Brandi Freeman, Sarah E Gilbert, Jennifer M Folster, Magdalena Medrzycki, Patricia L Shewmaker, Bettina Bankamp, Kay W Radford, Raydel Anderson, Michael D Bowen, Jeanne Negley, Sujan C Reddy, John A Jernigan, Allison C Brown, L Clifford McDonald, Preeta K Kutty

Descripción

To address high COVID-19 burden in U.S. nursing homes, rapid SARS-CoV-2 antigen tests have been widely distributed in those facilities. However, performance data are lacking, especially in asymptomatic people. To evaluate the performance of SARS-CoV-2 antigen testing when used for facility-wide testing during a nursing home outbreak. A prospective evaluation involving 3 facility-wide rounds of testing where paired respiratory specimens were collected to evaluate the performance of the BinaxNOW antigen test compared with virus culture and real-time reverse transcription polymerase chain reaction (RT-PCR). Early and late infection were defined using changes in RT-PCR cycle threshold values and prior test results. A nursing home with an ongoing SARS-CoV-2 outbreak. 532 paired specimens collected from 234 available residents and staff. Percentage of positive agreement (PPA) and percentage of negative agreement (PNA) for BinaxNOW compared with RT-PCR and virus culture. BinaxNOW PPA with virus culture, used for detection of replication-competent virus, was 95%. However, the overall PPA of antigen testing with RT-PCR was 69%, and PNA was 98%. When only the first positive test result was analyzed for each participant, PPA of antigen testing with RT-PCR was 82% among 45 symptomatic people and 52% among 343 asymptomatic people. Compared with RT-PCR and virus culture, the BinaxNOW test performed well in early infection (86% and 95%, respectively) and poorly in late infection (51% and no recovered virus, respectively). Accurate symptom ascertainment was challenging in nursing home residents; test performance may not be representative of testing done by nonlaboratory staff. Despite lower positive agreement compared with RT-PCR, antigen test positivity had higher agreement with shedding of replication-competent virus. These results suggest that antigen testing could be a useful tool to rapidly identify contagious people at risk for transmitting SARS-CoV-2 during nascent outbreaks and help reduce COVID-19 burden in nursing homes. None.

Fecha

2021

Identificador

10.7326/M21-0422

Fuente

Annals of internal medicine

Archivos

https://socictopen.socict.org/files/to_import/pdfs/72eab696ae01631f5e614824d0b008ba.pdf

Colección

Citación

Susannah L McKay, Farrell A Tobolowsky, Erin D Moritz, Kelly M Hatfield, Amelia Bhatnagar, Stephen P LaVoie, David A Jackson, K Danielle Lecy, Jonathan Bryant-Genevier, Davina Campbell, Brandi Freeman, Sarah E Gilbert, Jennifer M Folster, Magdalena Medrzycki, Patricia L Shewmaker, Bettina Bankamp, Kay W Radford, Raydel Anderson, Michael D Bowen, Jeanne Negley, Sujan C Reddy, John A Jernigan, Allison C Brown, L Clifford McDonald, Preeta K Kutty, “Performance Evaluation of Serial SARS-CoV-2 Rapid Antigen Testing During a Nursing Home Outbreak.,” SOCICT Open, consulta 27 de abril de 2026, https://socictopen.socict.org/items/show/6659.

Formatos de Salida

Position: 20140 (13 views)