Evaluation of RT-qPCR and Loop-Mediated Isothermal Amplification (LAMP) Assays for the Detection of SARS-CoV-2 in Argentina

Título

Evaluation of RT-qPCR and Loop-Mediated Isothermal Amplification (LAMP) Assays for the Detection of SARS-CoV-2 in Argentina

Autor

María Dolores Fellner, Romina Bonaventura, Jorge Basiletti, Martín Avaro, Estefanía Benedetti, Ana Campos, María Elena Dattero, Mara Russo, Sara Vladmirsky, Viviana Molina, Lucía Irazu, Marcelo A. Rodriguez, Andrea Pontoriero, Daniel M. Cisterna, Elsa G. Baumeister

Descripción

Our aim was to evaluate the analytical and clinical performance of the SARS-CoV-2 molecular detection kits used in Argentina. Nine real-time reverse-transcription polymerase chain reaction (RT-qPCR) and three reverse-transcription loop-mediated isothermal amplification (RT-LAMP) assays were evaluated using the World Health Organization (WHO) recommended test as reference method. A secondary standard calibrated for the E, N and RdRp genes against the Pan American Health Organization—World Health Organization—International Standard was used to calculate the limit of detection (LoD). A panel of artificial clinical samples, 32 positive and 30 negative for SARS-CoV-2, were analyzed to estimate the kappa concordance (κ) and the diagnostic performance. Differences among the LoD values for the target genes amplified by each kit were >1 log copies/reaction. The κ for the RT-qPCR kits was greater than 0.9, whereas that for the RT-LAMP assays ranged from 0.75 to 0.93. The clinical performance of RT-qPCR kits showed 100% specificity and high sensitivity, although with variations according to the gene analyzed. The E and N genes provided greater clinical sensitivity, whereas the RdRp gene increased the clinical specificity. The RT-LAMP assays revealed a variable diagnostic performance. The information provided can be useful to choose the most appropriate diagnostic test and may contribute to the establishment of a consensus in the diagnosis of SARS-CoV-2 in Argentina and the region.

Fecha

2021

Materia

SARS-CoV-2, RT-qPCR, RT-LAMP

Identificador

10.3390/genes12050659

Fuente

Epidemiology and Health

Editor

Korean Society of Epidemiology

Cobertura

Genetics

Archivos

https://socictopen.socict.org/files/to_import/pdfs/a664d61c69ded7b155a01987c32d3d44.pdf

Colección

Citación

María Dolores Fellner, Romina Bonaventura, Jorge Basiletti, Martín Avaro, Estefanía Benedetti, Ana Campos, María Elena Dattero, Mara Russo, Sara Vladmirsky, Viviana Molina, Lucía Irazu, Marcelo A. Rodriguez, Andrea Pontoriero, Daniel M. Cisterna, Elsa G. Baumeister, “Evaluation of RT-qPCR and Loop-Mediated Isothermal Amplification (LAMP) Assays for the Detection of SARS-CoV-2 in Argentina,” SOCICT Open, consulta 10 de junio de 2026, http://socictopen.socict.org/items/show/9548.

Formatos de Salida

Position: 6015 (36 views)